Advanced Treatment Units in Cullman County
Four tanks doing the job that one tank plus good soil would have done for free.
That is the honest way to read what follows. A powered treatment system is not a better system in some abstract sense. It is the system you buy when the ground will not treat the water for you, and it earns its cost by producing effluent clean enough to be released into far less soil than a conventional field would need.
On the plateau the design almost always comes down to usable depth. The rules set a minimum vertical separation between the bottom of the trench and a restrictive horizon, and on a thin-soiled lot that separation is the binding constraint long before perc rate is. Where the rock is limestone there is a second constraint on top: an effluent disposal field must sit 300 ft from a cave, sinkhole or similar depression, which on a karst lot can remove most of the usable ground in one stroke.
What owning one is actually like
-
Something is always running
The compressor runs continuously. It is on your power bill, it makes a noise, and when it stops the system stops treating: quietly, and without telling you, until the alarm goes.
-
There are consumables
Disinfection tablets get used up. A system that has run out is a system discharging undisinfected effluent onto the lawn, which is both the thing the design exists to prevent and a compliance problem.
-
There is a service schedule, and it is not advisory
Alabama requires an onsite system to be operated and maintained so that it does not create a nuisance or a health hazard, under ADPH Chapter 420-3-1 and Code of Ala. 1975 §§22-26-1 et seq. Advanced treatment units carry the manufacturer service schedule on top of that.
-
It shows up when you sell
A buyer's lender and inspector will ask about it, and the answers are on file with the authority. See inspections.
The part owners tend to miss is that the rules also protect the ground, not just the hardware. A lot may not be built on or altered so that the disposal field or the reserve field is adversely affected, and it may not be subdivided below the permitted size without a fresh application. The shed, the pool and the extra driveway are all capable of breaking a permit that was perfectly good the day it was issued.
Is it worth it?
It is not a choice on most lots that need one. If the soil report rules out a conventional field, the alternatives are a powered system, an engineered alternative like a mound, or not building. Where there is a genuine choice, the trade is a lower install cost and no running cost against a higher install cost and a permanent service obligation, and the right answer depends on how long you plan to own the place.
A licensed site evaluator has to answer that with a soil test; nobody can tell from a map. Send us your address and we will have local licensed pros quote the evaluation and the install. Request free quotes →